What Is the Coloplast Titan Penile Prosthesis?
A detailed look at the Titan and Titan Touch inflatable implants, their components, sizing, and key features, explained by Dr. Tuncay Tas.
Table of Contents
What Is the Coloplast Titan?
Coloplast, a well-established medical device manufacturer, produces the Titan penile prosthesis to treat erectile dysfunction. Specifically, it is a three-piece inflatable implant. The surgeon places it surgically, so it can restore a natural-feeling erection on demand whenever the patient wants one.
Surgeons and patients recognize the Titan family for durability, reliability, and a natural feel. It works particularly well as a long-term solution, especially once other ED treatments have not succeeded. For a direct comparison against another leading brand, therefore, see our AMS 700 vs. Coloplast Titan guide.
The Three Components
- Inflatable cylinders: Two Bioflex® cylinders sit inside the penis and mimic the natural erection process, letting the patient achieve and maintain an erection when desired.
- Pump: A pump sits in the scrotum. By squeezing and releasing it, the patient manually inflates and deflates the cylinders, controlling the erection directly.
- Reservoir: A fluid reservoir sits in the lower abdomen or pelvic region, and it stores the fluid used to inflate the cylinders.
Want to know if Titan fits your case?
Dr. Tas reviews your anatomy and goals directly.
Sizing and Product Range
The Titan family covers a wide sizing range, from 11 cm to 28 cm. In addition, it offers two pump options to fit different patients. Standard and narrow-base cylinders come pre-connected to the pump, which simplifies the surgical process.
XL cylinders, at 24, 26, and 28 cm, arrive as separate components instead. As a result, the surgeon gains more flexibility for less common anatomical needs.
During surgery, the surgeon measures the corporal bodies directly to select the correct cylinder length. This step matters, because an undersized cylinder can lead to poor rigidity, while an oversized one raises the risk of erosion or discomfort. For this reason, precise intraoperative measurement, not a pre-set number, ultimately determines your final implant size.
Key Features of the Titan Touch
- Touch pump: A simple deflate button lets the patient release the erection with a single press.
- Bioflex® material: The cylinders use Bioflex®, which provides strength, girth, and rigidity that hold up over years of use.
- Lock-Out® valve: The Cloverleaf reservoir includes a Lock-Out® valve, which reduces the risk of auto-inflation.
- Hydrophilic coating: This coating absorbs the surgeon's chosen aqueous solution quickly, which lowers infection risk and eases surgical placement.
- Zero-degree proximal tubing: This design allows for straightforward surgical placement.
- Soft molded tip: The tip shape optimizes anatomic positioning inside the body.
Why Patients Choose the Coloplast Titan
Patients often choose the Titan for its combination of durability, a natural feel, and a wide sizing range. Notably, the hydrophilic coating and Lock-Out® valve directly address two of the most common patient concerns: infection risk and unwanted auto-inflation.
These design details matter in daily use, since the implant stays in the body permanently. Consequently, small engineering improvements like these add up to a more reliable, comfortable experience over years of use.
Coloplast Titan Clinical Outcomes and Satisfaction
Published research on three-piece inflatable implants, including the Titan, reports strong long-term results. Five-year Kaplan-Meier survival estimates for mechanical function run around 87% for Titan. Studies show no statistically significant difference from competing brands, so this figure reflects a device that holds up reliably over years of daily use.
Patient satisfaction runs high as well. In published series, roughly 79% of patients report great satisfaction after inflatable implant surgery, and more than two-thirds describe greater self-confidence afterward.
In fact, 82% of patients say they would choose the same operation again, a figure that speaks directly to real-world quality of life after surgery. Taken together, these numbers help explain why inflatable implants remain the gold standard for men whose erectile dysfunction has not responded to less invasive treatments.
| Outcome Measure | Reported Result |
|---|---|
| 5-year mechanical survival | Approximately 87% |
| Patients reporting great satisfaction | Approximately 79% |
| Patients who would repeat the surgery | Approximately 82% |
A Strong Option for Complex Anatomy and Peyronie's Disease
The Titan's broad range of standard and narrower cylinder options gives surgeons real flexibility for complex cases. Specifically, this matters for patients with significant scar tissue or corporal fibrosis, where the erectile chambers may not accept a uniform cylinder diameter evenly.
For this reason, surgeons frequently choose the Titan for men who need implant surgery alongside Peyronie's disease correction. In many of these cases, the surgeon combines implant placement with manual straightening or modeling of the plaque during the same procedure, addressing both curvature and erectile function together rather than in two separate surgeries. If curvature and erectile dysfunction affect you together, see our Peyronie's Disease Treatment guide for the full picture.
Is the Coloplast Titan Right for You?
As with any penile prosthesis, a consultation with a healthcare professional remains essential. Specifically, Dr. Tas assesses your needs, preferences, and potential risks before recommending Titan or an alternative brand.
During this consultation, expect a physical examination, a review of prior treatments you have tried, and a candid discussion of realistic outcomes. Dr. Tas also explains recovery timelines and answers any question about long-term care, so you can make a fully informed decision before scheduling surgery.
Still unsure whether implant surgery is the right step for you? In that case, see our When Should I Consider Penile Implant Surgery guide first.
Long-Term Care and Maintenance
Once healed, a Titan implant needs very little daily attention. Most patients simply use it as intended and schedule an annual check-up so Dr. Tas can confirm the pump, reservoir, and cylinders all function correctly. These visits catch minor issues early, well before they turn into a problem requiring surgery.
Some men worry about the device wearing out with frequent use, but Coloplast engineers the Titan's Bioflex® cylinders specifically for daily cycling, so normal use does not accelerate wear in any meaningful way. If you do notice a change, such as difficulty inflating fully or unusual pain, contact the clinic promptly rather than waiting for your next scheduled visit.
Most manufacturers also back their inflatable implants with a limited warranty covering mechanical failure for a defined period after surgery. Ask Dr. Tas for the specific warranty terms that apply to your device during your consultation, since coverage details can change between product generations.

Assoc. Prof. Dr. Tuncay Tas
Board-Certified Urologist & Male Sexual Health Specialist, based in Istanbul. Dr. Tas assesses each patient's needs and anatomy before recommending the Coloplast Titan or an alternative implant brand.
Frequently Asked Questions
What sizes does the Titan implant come in?
What is the Touch pump feature?
What material are the cylinders made from?
Does the Titan reduce infection risk?
How is the Titan different from the AMS 700?
Who decides if I qualify for a Titan implant?
How long does a Titan implant last?
Is the Titan a good choice if I also have Peyronie's disease?
How is my exact implant size determined?
What happens during a Titan consultation?
Does daily use wear out the implant faster?
Is the Titan implant covered by a warranty?
Send Us a Message
Ready to Discuss the Coloplast Titan?
Book a confidential consultation with Assoc. Prof. Dr. Tuncay Tas in Istanbul.